Patient weight [kg] = 102; Nucleus = "H1"; SmartSelect = "yes"; Coil 1 (exclude) = "None"; Uniformity = "CLEAR"; FOV RL (mm) = 240; AP (mm) = 240; FH (mm) = 200; Voxel size RL (mm) = 3.75; AP (mm) = 3.75; Slice thickness (mm) = 4; Recon voxel size (mm) = 3.75; Fold-over suppression = "no"; Reconstruction matrix = 64; SENSE = "yes"; P reduction (AP) = 2; k-t BLAST = "no"; Stacks = 1; type = "parallel"; slices = 50; slice gap = "user defined"; gap (mm) = 0; slice orientation = "transverse"; fold-over direction = "AP"; fat shift direction = "P"; Stack Offc. AP (P=+mm) = -32.276413; RL (L=+mm) = -5.90813494; FH (H=+mm) = 18.3093834; Ang. AP (deg) = 2.83938247e-021; RL (deg) = -0; FH (deg) = -0; Free rotatable = "no"; Minimum number of packages = 1; Slice scan order = "ascend"; Large table movement = "no"; PlanAlign = "no"; REST slabs = 0; Catheter tracking = "no"; Interactive positioning = "no"; Allow table movement = "no"; Patient position = "head first"; orientation = "supine"; Scan type = "Imaging"; Scan mode = "MS"; technique = "FFE"; Contrast enhancement = "no"; Acquisition mode = "cartesian"; Fast Imaging mode = "EPI"; shot mode = "single-shot"; Echoes = 1; partial echo = "no"; shifted echo = "no"; TE = "user defined"; (ms) = 25; Flip angle (deg) = 80; TR = "user defined"; (ms) = 3000; Halfscan = "no"; Water-fat shift = "minimum"; RF Shims = "fixed"; Shim = "auto"; mDIXON = "no"; Fat suppression = "no"; Water suppression = "no"; MTC = "no"; Research prepulse = "no"; Diffusion mode = "no"; Elastography mode = "no"; Transmit channels = "both"; SAR mode = "high"; B1 mode = "default"; SAR Patient data = "auto"; PNS mode = "high"; Gradient mode = "maximum"; SofTone mode = "no"; Cardiac synchronization = "no"; Heart rate > 250 bpm = "no"; Respiratory compensation = "no"; Navigator respiratory comp = "no"; Flow compensation = "no"; Temporal slice spacing = "default"; fMRI echo stabilisation = "no"; NSA = 1; Angio / Contrast enh. = "no"; Quantitative flow = "no"; Manual start = "yes"; Dynamic study = "individual"; dyn scans = 120; recon multiplier = 1; dyn scan times = "shortest"; fov time mode = "default"; dummy scans = 0; immediate subtraction = "no"; fast next scan = "no"; synch. ext. device = "no"; dyn stabilization = "no"; prospect. motion corr. = "yes"; Keyhole = "no"; Arterial Spin labeling = "no"; Preparation phases = "full"; Interactive F0 = "no"; SmartPlan survey = "no"; B0 field map = "no"; B1 field map = "no"; MIP/MPR = "no"; SWIp = "no"; Images = "M", (3) "no"; Autoview image = "M"; Calculated images = (4) "no"; Reference tissue = "Grey matter"; EPI 2D phase correction = "no"; Recon compression = "No"; Preset window contrast = "soft"; Reconstruction mode = "real time"; reuse memory = "no"; Save raw data = "no"; Hardcopy protocol = "no"; Image filter = "system default"; Geometry correction = "default"; IF_info_seperator = 1634755923; Total scan duration = "06:09.0"; Rel. SNR = 1; Act. TR/TE (ms) = "3000 / 25"; Dyn. scan time = "00:03.0"; Time to k0 = "00:01.5"; ACQ matrix M x P = "64 x 62"; ACQ voxel MPS (mm) = "3.75 / 3.87 / 4.00"; REC voxel MPS (mm) = "3.75 / 3.75 / 4.00"; Scan percentage (%) = 96.875; Packages = 1; Min. slice gap (mm) = -0; EPI factor = 31; Act. WFS (pix) / BW (Hz) = "6.306 / 68.9"; BW in EPI freq. dir. (Hz) = "3280.0"; Min. WFS (pix) / Max. BW (Hz) = "5.141 / 84.5"; Min. TR/TE (ms) = "1694 / 8.4"; SAR / head = "< 18 %"; Whole body / level = "< 0.1 W/kg / normal"; SED = " 0.0 kJ/kg"; B1+rms / Coil Power = "0.99 uT / 18 %"; Max B1+rms = "0.99 uT"; PNS / level = "73 % / normal"; dB/dt = "49.1 T/s"; Sound Pressure Level (dB) = 17.0739899;